1. Inverter Sungrow SG10KTL-M Specifications:
Technical data | Detail |
Dimensions (H x W x D) | 370 × 485 × 160 mm |
Mass | 20 kg |
Protection level | IP65 |
Power consumption at night | <1 W |
Operating temperature range | -25 -> 60 ° C |
Allowable humidity (no condensation) | 0 – 100% |
Cooling method | Smart forced-air cooling |
Maximum operating altitude (above sea level) | 4000 m (capacity reduced from 3000m) |
Display | LED, Bluetooth + APP |
Communication | RS485, Wifi, Ethernet |
Standard | IEC / EN 62109-1, IEC / EN 62109-2, IEC / EN 61000-3-11, IEC / EN 61000-3-12, UTE
15-712-1, IEC 61727, IEC 62116, VDE0126-1-1 / 4105, G59 / 3, CEI 0-21, UNE 206007-1, EN50438: 2013 |
Support grid | Control reactive and reactive power |
Standard DC connection | MC4 (maximum area of 6 mm²) |
Standard AC connection | Plug and play connector (maximum cross-section 16 mm²) |
Efficiency | 98.6% |
Input specification (DC) | Detail |
Maximum input voltage | 1100 V |
Minimum input voltage / Start | 200 V / 250 V |
Input voltage level | 600 V |
MPP voltage range | 200 – 1000 V |
MPP voltage range for rated power | 470 – 850 V |
Number of independent MPP inputs | 2 |
Maximum number of strings per MPPT | first |
Maximum input current | 22A (11 A / 11 A) |
Maximum current for input connection | 15 A |
Maximum DC short-circuit current | 30 A (15 A / 15 A) |
Output parameters (AC) | Detail |
AC output power | 11 kVA * @ 35 ℃ / 10 kVA @ 45 ℃ |
Maximum AC output current | 16.5 A |
Rated AC voltage | 3 / N / PE, 230/400 V |
AC voltage range | 270 – 480 V |
Rated power grid frequency range | 50 Hz / 45 – 55 Hz, 60 Hz / 55 – 65 Hz |
Total harmonic power | <3% |
Power factor / Power system range | 0.8 early phase -> 0.8 late phase |
Number of electric phases | 3 |
Protect | |
AC short circuit | Have |
LVRT | Have |
Leakage current protection | Have |
Reverse polarity DC | Have |
Monitoring grid parameters | Have |
Monitor the current for each series | Have |
DC switch | Have |
AC switch | Is not |
PID recovery function | Option |
Over voltage protection | DC Type II / AC Type II |
2. Inverter Sungrow SG10KTL-M connection diagram
3. 05 advantages of SG10KTL-M
Stt | Highlights |
first | PID recovery feature is patented |
2 | Update software via OTA |
3 | Maximum efficiency of 98.6% |
4 | The smart meter accurately measures each number |
5 | Comprehensive monitoring via App or Web |